UFx.py version 1.6 from 07/16/2018
Page 1 of 2
Created by user vjeran on 07/17/2018 14:30:10
SLAC Moving Stretched Wire Magnetic Field Measurement Summary
Magnet ID : | Calibration |
Directory : | S:\magdata\LCLS-II\Phase Shifter\Calibration\126Gcm_+By_center\Final Results\Stretched Wire |
Date : | 06-29-2018 |
Time : | 11:12:25 - 12:16:51 |
Operator : | VV |
Project : | LCLS-II |
Device Type : | Phase Shifter |
Run Number : | 1 |
Data Type : | |
Run Comment : | 126 Gauss*cm magnet, +By, center pos |
gap | I1Y | I2Y | I1X | I2X |
- |
109.9 0.3 (5) |
22.3 0.1 (5) |
3.4 0.5 (4) |
1.0 0.3 (5) |
integral | gap | -02.00;+00.00 | -01.00;+00.00 | +00.00;+00.00 | +01.00;+00.00 | +02.00;+00.00 |
I1Y |
- |
105.0 5.9 (3) |
108.8 0.9 (3) |
105.3 6.1 (3) |
108.8 0.9 (3) |
108.5 0.7 (3) |
I2Y |
- |
21.9 0.3 (3) |
22.0 0.2 (2) |
21.8 0.2 (3) |
22.2 0.1 (2) |
21.9 0.2 (3) |
I1X |
- |
4.1 0.4 (3) |
4.0 0.9 (3) |
4.3 0.6 (3) |
3.5 0.7 (3) |
3.8 0.9 (3) |
I2X |
- |
1.0 0.2 (3) |
0.8 0.1 (3) |
1.0 0.3 (3) |
0.8 0.0 (3) |
0.9 0.3 (3) |
integral | gap | +00.00;-02.00 | +00.00;-01.00 | +00.00;+00.00 | +00.00;+01.00 | +00.00;+02.00 |
I1Y |
- |
105.9 9.5 (2) |
109.3 0.1 (2) |
99.1 0.0 (1) |
109.5 0.4 (3) |
104.2 7.2 (2) |
I2Y |
- |
21.5 1.6 (3) |
22.2 0.1 (3) |
22.3 0.2 (3) |
22.2 0.2 (2) |
22.2 0.2 (3) |
I1X |
- |
3.5 0.2 (3) |
0.8 0.4 (3) |
2.4 1.7 (3) |
1.7 1.2 (3) |
1.5 1.5 (3) |
I2X |
- |
1.1 0.0 (2) |
0.3 0.1 (3) |
0.8 0.5 (3) |
0.4 0.1 (3) |
0.6 0.4 (3) |
UFx.py version 1.6 from 07/16/2018
Page 2 of 2
Created by user vjeran on 07/17/2018 14:30:10
SLAC Moving Stretched Wire Magnetic Field Measurement Summary
Magnet ID : | Calibration |
Directory : | S:\magdata\LCLS-II\Phase Shifter\Calibration\126Gcm_+By_center\Final Results\Stretched Wire |